CATALOGUE PRODUCT

ASD300-TH-WH2-P12-C-400

Switch Cabinet Integrated Measuring and Control Device

ASD300 configuration with 12 wireless temperature points, two temperature/humidity control circuits and communication, as identified by its catalog ordering code.

← All products
ASD300-TH-WH2-P12-C-400 Switch Cabinet Integrated Measuring and Control DeviceASD300-TH-WH2-P12-C-400 product photograph extracted from the supplied catalogue.

PRODUCT IDENTITY

Catalogue record

Source catalogue
SST固态变压器配套产品明细.xls
Original product name
开关柜智能操控装置
Catalogue model
ASD300-TH-WH2-P12-C-400
Source location
Sheet1, row 4
Catalogue installation location
中置柜
Image source
Sheet1!E4 · xl/media/image4.jpeg
Source notes
  • The exact catalog ordering code is retained. The TH, WH2, P12, C and 400 fields are decoded from Figure 1.1.
  • The 100 V /5 A entries are the ASD300 metering inputs; they are not the switchgear system-voltage rating.
  • Wireless temperature, electrical metering and communication must not be generalized to every ASD family member.
01Primary-circuit mimic and switch-state indication
02Two temperature/humidity control circuits (WH2)
0312 wireless temperature points with ATE400 designation (P12-400)

PRODUCT OVERVIEW

Product information

The manual's naming rule identifies T as the opening/closing, remote/local and charging switches; H as charging indication; WH2 as two temperature/humidity control circuits; P12 as 12 wireless temperature points; C as communication; and 400 as ATE400 wireless temperature sensors. The ASD300 base model also provides the metering functions shown in its model table.

Listed model

ASD300-TH-WH2-P12-C-400

TECHNICAL DETAILS

Specifications and their sources

Switchgear application
3-35 kV indoor switchgearSource: ASD V3.2, PDF p.6, section 1.1 Product overview
T / H configuration
Opening/closing, remote/local and charging switches; charging indicationSource: ASD V3.2, PDF p.7, Figure 1.1 Product naming rule
Temperature/humidity control
WH2: two temperature/humidity control circuitsSource: ASD V3.2, PDF p.7, Figure 1.1 Product naming rule
Wireless temperature configuration
P12: 12 points; 400: ATE400 sensorsSource: ASD V3.2, PDF p.7, Figure 1.1 Product naming rule
Auxiliary supply
AC 85-265 V or DC 100-300 VSource: ASD V3.2, PDF p.10, Table 2 ASD Series Technical data
ASD300 metering inputs
100 V; 5 A; 50 Hz; 3P3L or 3P4LSource: ASD V3.2, PDF p.9, Table 2 ASD300 Rated input column
Communication
RS485; Modbus RTU; 2400 /4800 /9600 /19200 bpsSource: ASD V3.2, PDF pp.9-10, Tables 1-2 communication rows
Wireless temperature range / accuracy
-50 to +125 °C /±1 °CSource: ASD V3.2, PDF p.10, Table 2 ASD300 wireless temperature rows
ATE400 starting current
≥5 ASource: ASD V3.2, PDF p.10, Table 2 starting-current row; ATE V2.9, PDF pp.5-6, ATE400 table
Operating environment
-10 to +55 °C; relative humidity ≤95%Source: ASD V3.2, PDF p.10, Table 2 Environmental requirement

CATALOGUE IMAGES

Additional views from the catalogue

Original catalogue product photograph, cell F4.
Original catalogue product photograph, cell F4.Catalogue · Sheet1!F4
Original catalogue product photograph, cell G4.
Original catalogue product photograph, cell G4.Catalogue · Sheet1!G4
Original catalogue product photograph, cell H4.
Original catalogue product photograph, cell H4.Catalogue · Sheet1!H4

CATALOGUE APPLICATION

Listed installation context

01SST withdrawable switchgear cabinet

SOURCE DOCUMENTS

Original product manuals

ASD Switch Cabinet Integrated Measuring and Control Device — Installation and Operation Instruction

Chinese / English · V3.2 · Relevant PDF pages 6, 7, 8, 9, 10

Download original manual ↓

PRODUCT QUESTIONS

Questions about this model

What does P12-C-400 identify?

The naming rule identifies P12 as 12 wireless temperature points, C as communication and 400 as ATE400 wireless temperature sensors.

What does TH-WH2 identify?

T selects opening/closing, remote/local and charging switches; H selects charging indication; WH2 selects two temperature/humidity control circuits.

Are these features shared by every ASD model?

No. These fields describe the catalog's ASD300-TH-WH2-P12-C-400 configuration. The manual assigns different functions to other ASD base models and ordering codes.

PROJECT SUPPORT

Evaluating ASD300-TH-WH2-P12-C-400?

Send the application, voltage, required functions, quantity and target delivery date.

Send project requirements →