CATALOGUE PRODUCT

ARTM-8L

Temperature Patrol Tester

Eight-channel wired temperature measurement and control instrument for low-voltage electrical contacts, transformer windings and motor windings.

← All products
ARTM-8L Temperature Patrol TesterARTM-8L product photograph extracted from the supplied catalogue.

PRODUCT IDENTITY

Catalogue record

Source catalogue
SST固态变压器配套产品明细.xls
Original product name
有线测温装置
Catalogue model
ARTM-8L
Source location
Sheet1, row 20
Catalogue installation location
输出柜
Image source
Sheet1!E20 · xl/media/image28.jpeg
Source notes
  • Maximum supported sensor ranges do not establish the range of an unspecified sensor assembly.
  • The optional temperature/humidity input is not described as a standard included component.
018 measurement channels
02NTC, PT100/PT1000, thermocouple and 0-5 V inputs
035 normally-open alarm outputs

PRODUCT OVERVIEW

Product information

The ARTM-8L accepts the specified NTC sensors, three-wire PT100/PT1000, K/T/J/E/N thermocouples and 0-5 V inputs. Its sensor-dependent measurement ranges, five normally-open alarm outputs, three analogue retransmission outputs and RS485 communication are listed in the manual's technical table.

Listed model

ARTM-8L

TECHNICAL DETAILS

Specifications and their sources

Measurement channels
8Source: ARTM-8L T1.3, PDF p.7, section 1.2 Technical Features
Input signals
Specified NTC types; three-wire PT100/PT1000; K/T/J/E/N thermocouples; 0-5 VSource: ARTM-8L T1.3, PDF p.7, Input signal rows
NTC measurement range / accuracy
-40 to +140 °C /±1 °CSource: ARTM-8L T1.3, PDF p.8, Measurement Range and Accuracy class
PT100/PT1000 measurement range
Maximum supported -200 to +850 °C; actual range depends on the sensorSource: ARTM-8L T1.3, PDF p.8, Measurement Range
PT100/PT1000 accuracy
-200 to +200 °C: ±1 °C; above +200 to +850 °C: ±1%Source: ARTM-8L T1.3, PDF p.8, Accuracy class (standard signal)
Thermocouple range / accuracy
Maximum supported -200 to +1372 °C, actual range depends on thermocouple type; 1%Source: ARTM-8L T1.3, PDF p.8, Measurement Range and Accuracy class
Auxiliary supply / consumption
AC 85-265 V /DC 100-300 V; ≤2 WSource: ARTM-8L T1.3, PDF p.8, Auxiliary power
Alarm outputs
5 groups normally open; AC 250 V /5 A or DC 30 V /5 ASource: ARTM-8L T1.3, PDF p.8, Alarm Output
Analogue retransmission
3 channels, 4-20 mASource: ARTM-8L T1.3, PDF p.9, Transmit output
Communication
RS485, Modbus RTU; 2400 /4800 /9600 /19200 bpsSource: ARTM-8L T1.3, PDF p.9, Communication
Operating environment / mounting
-20 to +55 °C, humidity ≤95%; panel or DIN35 rail mountingSource: ARTM-8L T1.3, PDF p.9, Environment and section 1.3

CATALOGUE IMAGES

Additional views from the catalogue

Original catalogue product photograph, cell F20.
Original catalogue product photograph, cell F20.Catalogue · Sheet1!F20
Original catalogue product photograph, cell G20.
Original catalogue product photograph, cell G20.Catalogue · Sheet1!G20
Original catalogue product photograph, cell H20.
Original catalogue product photograph, cell H20.Catalogue · Sheet1!H20

CATALOGUE APPLICATION

Listed installation context

01SST output cabinet

SOURCE DOCUMENTS

Original product manuals

ARTM-8L Temperature Patrol Tester — Operation Manual

Chinese / English / Russian · T1.3 · Relevant PDF pages 6, 7, 8, 9

Download original manual ↓

PRODUCT QUESTIONS

Questions about this model

Is the same temperature range available with every sensor?

No. The table gives different ranges and accuracies for NTC, PT100/PT1000 and thermocouple inputs. The actual PT100/PT1000 and thermocouple ranges depend on the selected sensor.

How many alarm and retransmission outputs are listed?

The manual lists five normally-open alarm-output groups and three 4-20 mA retransmission channels.

Is the additional temperature/humidity input standard?

The manual identifies one temperature/humidity input as optional.

PROJECT SUPPORT

Evaluating ARTM-8L?

Send the application, voltage, required functions, quantity and target delivery date.

Send project requirements →